Hochgenauige Hochspannungskondensator Ladeversorgung
Holen Sie sich aktuelle PreisZahlungsart: | T/T |
Incoterm: | FOB,CFR,CIF,EXW |
Minimum der Bestellmenge: | 1 Piece/Pieces |
Transport: | Ocean,Land,Air,Express |
Hafen: | SHANGHAI,NANJING,QINGDAO |
Zahlungsart: | T/T |
Incoterm: | FOB,CFR,CIF,EXW |
Minimum der Bestellmenge: | 1 Piece/Pieces |
Transport: | Ocean,Land,Air,Express |
Hafen: | SHANGHAI,NANJING,QINGDAO |
Modell: CCP - 6U
Marke: Idealteknic
Herkunftsort: China
Ausgangsleistung: > 500W
Input Voltage: Three Phase 380vac
Input Frequency: 50/60hz
Working Principle: Pwm
Power Supply Type: Igbt-Based
Working Mode: Constant Voltage / Constant Current
Display Mode: Digital Led
Control Mode: 10-Turn Potentiometers
Protections: Ocp, Short Circuit And Load Discharging Protections Etc., Ocp, Short Circuit And Load Dischargin
Applications: Lab Test / Hipot / Capacitor Charging
Circuit Mode: Pwm
Output Voltage Range: 1 Kv ~ 100 Kv
Output Current Range: 60 Ma ~ 6000 Ma
Ausgabetyp: Single
Cooling: Forced Air Cooling
Verkaufseinheiten | : | Piece/Pieces |
Pakettyp | : | Sperrholzkiste |
Bildbeispiel | : | |
Herunterladen | : |
Hochspannungskondensator der CCP -Serie DC Netzteil laden
Überblick
Die Hochspannungsversorgungen der CCP-6U-Serie erweitert und verbessert die Ausgangskapazität auf der Grundlage des Ladeverbrauchs der CCP-4U-Hochspannungskondensator. Es nimmt ein 19-Zoll-6U-Standard-Rack-Mount-Chassis an, die Ausgangsleistung kann 6 kW erreichen und der Ausgangsspannungsstand beträgt 1KV / 2KV / 3KV / 4KV / 5KV / 6KV / 8KV / 10KV / 12KV / 15KV / 20KV / 30KV / 30KV / 40 kV / 50 kV / 60 kV / 70 kV / 80 kV / 100 kV erweitert diese Serie von Hochspannungskondensator-Ladungsnetzteilen die Ausgangsspannung und den Leistungsbereich auf der Grundlage der Aufrechterhaltung hoher Effizienz, hoher Reaktionsgeschwindigkeit mit hoher Ausgangsquote und schnelleren Schutzmerkmalen zur Selbstwiederherstellung.
Die Ausgangsspannung und der Strom des HV -Kondensator -Ladegeschmacks können gesteuert und durch das vordere Bedienfeld gelesen werden. Und diese Reihe von Kondensatorladungs -Hochspannungsstromversorgungen ist ebenfalls serienmäßig mit einer DB50 -Schnittstelle ausgestattet. Kunden können die Steuersoftware gemäß unserem Kommunikationsprotokoll bearbeiten oder 0 - 10 V -Signal- und Trockenkontaktsignal an der Schnittstelle anwenden und Lesungen.
Mit vollständigen Schutzfunktionen kann das HV -Kondensator -Ladegerät mit Überspannung, Überstrom, Lastentladung und anderen Situationen umgehen.
Merkmale
l Kann als HV -DC -Stromversorgung oder als HV -Kondensator -Lade -Stromversorgung verwendet werden.
l Ausgangsspannung einstellbar von 0 bis 100%
l Ausgangsleistung: Durchschnittliches Laden @ 3KJ/s und die Spitzenladekraft können 3 kW erreichen.
l Laden im konstanten Strommodus und wechseln Sie in konstantes Strommodus bis vollständig geladen.
l Einzigartiges doppeltes isoliertes System, starke Anti-Interferenz-Fähigkeit.
l Zwangsluftkühlung, sehr robustes Design.
Anwendungen
l Ionenstrahlimplantation.
l Halbleiterprozess.
l Elektronenstrahlschweißen.
l Kondensatorladung.
l Hochleistungs-HF-Sender.
l Elektrostatischer Filter.
l Röntgensystem.
1. Dieses Leistungsmodul verfügt über eine HV -Ausgabe, nur professionelle Person kann es bedienen.
2. Bitte stellen Sie vor dem Betrieb eine gute Erdung.
3. Kondensator-Ladeversorgung hat eine niedrige interne gespeicherte Energie, bitte kein Ladung.
4. Halten Sie das Kraftmodul sauber und gute Belüftung.
5. HV -Eingangs- und Ausgangsstecker oder HV -Last ohne Berührung etwas.
HINWEIS: Alle Modelle haben grundlegende Komplikationen, einschließlich Eingangsleitungen, HV -Zeile, GND -Zeile, Schnittstellenlinien ... usw.
Input |
Voltage |
Three-phase 380Vac (input tolerance: 10%) |
|
Frequency |
50Hz/60Hz |
||
Connection |
Input line provided by iDealTek. (1.5 meters) |
||
Output |
Rated power |
3KW ~ 6KW (Max.) available ** |
|
Output voltage adjusting range |
1KV / 2KV / 3KV / 4KV / 5KV / 6KV / 8KV / 10KV / 12KV / 15KV / 20KV / 30KV / 40KV / 50KV / 60KV / 70KV / 80KV / 100KV available ** (For other output voltages, please contact us for details) |
||
Output current adjusting range |
0A ~ ****mA |
||
Output polarity |
Positive or Negative (both available) Client must choose one output polarity before ordering. |
||
Line regulation |
≤0.1% for ±10% change in input voltage. |
||
Load regulation |
≤0.1% for no load to full load at output. |
||
Ripple (Vr.m.s.) |
≤0.1% @ rated output. |
||
Output connection |
Detachable shielded high-voltage cable provided by IdealTek. (3 meters) |
||
Efficiency |
≥90% |
||
Setting & Display |
Output control mode |
Local |
10-turn potentiometer on front panel. |
Remote |
DB50 analog port & RS485 communication port. |
||
Display mode |
Display mode |
41/2 LED digital display |
|
Display resolution |
≤1% (range: 5%~100% of the rated value) |
||
Protection & Monitoring functions |
Load discharging protection |
When the load has discharging due to insufficient safety distance between load and ground, the power supply shutdown the high voltage output, and then restarts, so cycle like this till the discharging fault is eliminated. |
|
Short circuit protection |
When a short circuit occurs between the load and the ground, the power supply works in constant current mode, the current is limited to the maximum value, and the voltage drops to 0 to protect the internal inverter from damage. |
||
Over current protection |
When the users' load exceeds the rated load and cause over-loading, the power supply works in constant current mode, the power supply output current does not change, and output voltage decreases. |
||
Noise |
≤65dB |
||
Protection degree |
IP20 |
||
Cooling method |
Forced air cooling (Front inlet, rear outlet) |
||
Working environment conditions |
Ambient temperature |
0℃~40℃ |
|
Humidity |
10%~90% (non-condensing) |
||
Height |
≤2000m |
||
Storage environment conditions |
Ambient temperature |
-20℃~60℃ |
|
Humidity |
10%~90%(non-condensing) |
||
Height |
≤2000m |
||
Size (W*H*D) (mm) |
483*266*573 (19” sub-rack 6U chassis) |
||
Weight |
45KG (1KV ~ 10KV) 55KG (20KV ~ 100KV) |
||
|
Front panel description |
||
|
||
No. |
Description |
|
1 |
Power Switch (POWER) |
|
2 |
HV ON / OFF Switch (HV) |
|
3 |
Local / Remote Switch (LOCAL / REMOTE) |
|
4 |
Analog / RS communication Switch |
|
5 |
HV adjusting knob |
|
6 |
Current adjusting knob |
|
7 |
HV output display |
|
8 |
Output current display |
|
9 |
Emergency Button |
|
10 |
Reset switch |
|
Front Panel Indicator Lights Description |
||
|
||
Indicator lights name |
Description |
|
POWER ON |
After the CONTROL POWER switch is set to the ON position, the light becomes on, indicating that the power input has been connected and the power supply is normal. |
|
HV ON |
After the HV switch is set to the ON position, the light becomes on, indicating that the high-voltage output of the power supply is started and the power supply is normal. |
|
CONST HV
|
When the light is on, it indicates that the power supply is working in a constant voltage state. |
|
CONST mA |
When the light is on, it indicates that the power supply is working in a constant current state. |
|
CONST POW |
When the light is on, it indicates that the power supply is working in a constant power state. |
|
OVER VOLTAGE |
When the light is on, it indicates that the power supply has a high voltage overvoltage fault. |
|
INV OVERI |
This light is on, indicating that the power supply has an inverter overcurrent fault. |
|
INV OVER TEMP |
This light is on, indicating that the power supply has an inverter over-temperature fault. |
|
HV OVER TEMP |
When the light is on, it indicates that the power supply has an over-temperature fault with the high-voltage part. |
|
SPARK EXCEEDED |
When the light is on, it indicates that the power supply has a discharge fault. |
|
AC FAULT |
When the light is on, it indicates that there is an AC fault (overvoltage or under voltage) fault in the power supply. |
|
EMERGENCY |
When the light is on, it indicates that the power supply is in an emergency stop state with faults. |
|
INTERLOCK |
When the light is on, it indicates that the power supply is in an interlocked state and the power supply is normal. |
|
Rear panel description |
||
|
||
Mark |
Description |
|
E1 |
Grounding bolt |
|
J1 |
HV output interface |
|
JB1 |
DB50 control interface |
|
CB1 |
Main power switch |
|
LINE INPUT |
Power Supply input interface Three – phase, four – wire (L1 è Black, L2 è Red, L3 è Grey, Null è Blue, PE è Green) |
|
AIR EXHAUST |
Cooling fans |
KV |
mA |
P (KW) |
Model |
KV |
mA |
P (KW) |
Model |
1 |
6000 |
6 |
CCP-(N/P)6kW-1kV |
15 |
400 |
6 |
CCP-(N/P)6kW-15kV |
2 |
3000 |
6 |
CCP-(N/P)6kW-2kV |
20 |
300 |
6 |
CCP-(N/P)6kW-20kV |
3 |
2000 |
6 |
CCP-(N/P)6kW-3kV |
30 |
200 |
6 |
CCP-(N/P)6kW-30kV |
4 |
1500 |
6 |
CCP-(N/P)6kW-4kV |
40 |
150 |
6 |
CCP-(N/P)6kW-40kV |
5 |
1200 |
6 |
CCP-(N/P)6kW-5kV |
50 |
120 |
6 |
CCP-(N/P)6kW-50kV |
6 |
1000 |
6 |
CCP-(N/P)6kW-6kV |
60 |
100 |
6 |
CCP-(N/P)6kW-60kV |
8 |
750 |
6 |
CCP-(N/P)6kW-8kV |
70 |
86 |
6 |
CCP-(N/P)6kW-70kV |
10 |
600 |
6 |
CCP-(N/P)6kW-10kV |
80 |
75 |
6 |
CCP-(N/P)6kW-80kV |
12 |
500 |
6 |
CCP-(N/P)6kW-12kV |
100 |
60 |
6 |
CCP-(N/P)6kW-100kV |
|
l 0 ~ 10V Analogsignalsteuerung (DB50 -Schnittstelle)
l RS -Kommunikationsschnittstelle (RS485 -Kommunikationsport)Zeichnungen (nur als Referenz) |
6U -Chassis (2 kW ) (Ral7035) |
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.